Testing Laboratory

 

Our Testing Laboratory was established to ensure that Unilamp's lighting products surpass the design and quality standards specified by international regulations and are accredited to ISO 17025 by internationally recognized ILAC MRA and NAC.
 

 

All Unilamp luminaires are tested in accordance with the requirements of the following international standards:

– Photometric Test
– Thermal Test (normal operation) Clause 12.4
– IP Test Clause 9.2
– Humidity Test
– Endurance Test
– IK Test
– Salt Spray Test

 

Laboratory Accreditation

 

Photometric Test

At Unilamp, we have an in-house testing facility that can test and issue full reports of IES LM-79-08 for our customers. The test method is carried out according to IES manuals and procedures.

*Please get in touch with our sales representatives for more details.

→ Standard CIE 121-1996 (Accredited with ILAC & TISI)
→ Standard IES LM-79-08 (Accredited with ILAC & TISI)
→ Standard ANSI/IES LM-79-19 (Accredited with ILAC & TISI)

 

 

 

LM-79 Report

LM-79 testing captures performance characteristics of products that feature solid-state lighting (SSL) technology, including light-emitting diodes (LEDs).

This testing provides a snapshot of performance under specified operating conditions at some point in a product's life, usually at the beginning of operation— these are referred to as initial measurements. It does not address lifetime ratings, changing performance over time (e.g., lumen maintenance), or LED case temperature.

The LM-79 method applies to integrated LED products, such as luminaires and replacement lamps. It does not apply to LED packages, modules, or arrays (herein collectively called LED light sources).

LM-79 data enables objective product comparisons and allows for evaluation relative to performance requirements. Although LM-79 does not prescribe a report format or the minimum content, a substantial list of "typical items reported" is provided. Key measurements addressed in the test report include electrical characteristics, lumen output, spatial distribution of light, and color attributes.

 

 

 

Endurance and Thermal Test

Our LED luminaires are designed and tested under ambient thermal conditions Ta 40°C and 50°C.

→ Standard IEC 60598-1 Edition 9.0 2014-05 (Accredited with ILAC & TISI)
→ Standard IEC 60598-1 Edition 9.0 2020-08 (Accredited with ILAC & TISI)
→ Standard IEC 60598-2-1 Edition 2.0 2020-01 (Accredited with ILAC & TISI)

Test under conditions representing cyclic heating and cooling in service; the luminaire shall not become unsafe or fail prematurely.

→ Standard IEC 60598-1 Edition 9.0 2020-08
→ Standard IEC 60598-2-1 Edition 2.0 2020-01

 

IP Test

Water jet test for ingress of liquid and moisture by water jet equipment.

Dust test for the ingression of harmful dust and solid particles.

→ Standard IEC 60598-1 Edition 9.0 2020-08 (Accredited with ILAC & TISI)
→ Standard IEC 60598-2-1 Edition 2.0 2020-01 (Accredited with ILAC & TISI)

 

Humidity Test

We test the luminaires under the high humidity environment for particular markets.

→ Standard IEC 60598-1 Edition 9.0 2020-08
→ Standard IEC 60598-2-1 Edition 2.0 2020-01

 

IK Test

Test for the degree of protection of the luminaire against harmful external mechanical impacts.

→ Standard IEC 60068-2-75
→ Standard IEC 62262 2002-02

 

 

Salt Spray Test

Test for the degree of corrosion resistance on the luminaire’s surface under a severe saline environment.

→ Standard ASTM B117-73

 

 

EMC Test

Test for electromagnetic compatibility, including harmonic current emissions, voltage fluctuation, and insertion loss.

 

 

Electrical Safety Test

Test for protection against electric shock, insulation resistance, and earth continuity.

 

 

Vacuum Test

Test verifying that there is no leakage on the products, especially In-ground luminaires and Underwater luminaires.

 

 

Wind Load Test

Simulation of strength analysis carried out under a strong wind environment.

 

 

Light Measurement

Our product testing is second to none, and you can be assured that at Unilamp, a thorough product testing process is followed, both at our factory and at any of our partner's premises. All luminaires that carry the Unilamp trademark fall under our guidelines for manufacture.

All Unilamp products are measured by a Goniophotometer and/or Integrate Sphere, which gives a surety of lighting design, and all files are in IES and LDT format.

 

In 2023, Unilamp's testing laboratory denominates to Unilab while expanding the scope of accreditation.

>>Download now for Unilab Brochure<<

Unilab service →

 

  • Testing Laboratory

CONTACT INFO

  •   461 Ramintra Road, Kannayao, Bangkok 10230 Thailand
  •   Tel : +66(0)2 943 2420-1, +66(0)2 946 4170-1
  •   Fax : +66(0)2 943 2419
  •   Email : online@unilamp.co.th

WORKING DAYS

  • MON. - FRI. 8.00 AM - 5.00 PM
  • TIME GMT +7
  • Privacy Policy

Follow Us